Volume 25 Issue 2
Apr.  2025
Turn off MathJax
Article Contents
LU Lin-feng, NIE Shao-feng, DING Song-lin, MA Zhong-yi, LI Rui, WANG Wei, RAFTERY Gary. Corrosion degradation of shear performance in friction-type connections with high-strength bolts for steel structures[J]. Journal of Traffic and Transportation Engineering, 2025, 25(2): 218-234. doi: 10.19818/j.cnki.1671-1637.2025.02.014
Citation: LU Lin-feng, NIE Shao-feng, DING Song-lin, MA Zhong-yi, LI Rui, WANG Wei, RAFTERY Gary. Corrosion degradation of shear performance in friction-type connections with high-strength bolts for steel structures[J]. Journal of Traffic and Transportation Engineering, 2025, 25(2): 218-234. doi: 10.19818/j.cnki.1671-1637.2025.02.014

Corrosion degradation of shear performance in friction-type connections with high-strength bolts for steel structures

doi: 10.19818/j.cnki.1671-1637.2025.02.014
Funds:

China Scholarship Council 202206560008

More Information
  • Corresponding author: NIE Shao-feng (1981-), male, professor, PhD, niesf@gfscw.cn
  • Received Date: 2024-01-02
  • Publish Date: 2025-04-28
  • In order to investigate and compare the effects of external and internal anti-corrosion coating on the shear performance in friction-type connections with high-strength bolts, a relevant experimental study was carried out. The preset conditions included the presence or absence of anti-corrosion coating on the friction surface, the presence or absence of external anti-corrosion coating, and the maintenance of external anti-corrosion coating. Under these conditions, shear performance tests before and after corrosion were carried out on 43 specimens featuring friction-type connections with high-strength bolts in 17 groups. Calibration tests were conducted on the anti-slip coefficient of the friction surface painted with epoxy zinc-rich primer, alcohol-soluble inorganic anti-rust and anti-slip primer for bridges, and sandblasted friction surfaces. Test results show that the anti-slip coefficient of sandblasted friction surfaces is 0.44, which does not meet the recommended code value. The anti-slip coefficient of the friction surface coated with epoxy zinc-rich primer is 0.27, and it is 0.50 when the friction surface is coated with alcohol-soluble inorganic anti-rust and anti-slip primer for bridges. Both values are higher than the recommended code value. A C4 atmospheric corrosion environment was artificially simulated, and an alternate wet and dry copper accelerated acetic acid salt spray test (CASS) was carried out. One-time corrosion tests were completed for specimens with sandblasted friction surfaces, epoxy zinc-rich primer, alcohol-soluble inorganic anti-rust and anti-slip primer for bridges, external anti-corrosion coating, and no corrosion protection. A second corrosion of the external anti-corrosion coating following maintenance was performed. The test results show that the acceleration of laboratory accelerated corrosion tests is predictable and controllable. Significant degradation of shear performance in friction-type connections with high-strength bolts is not prevented by external corrosion coatings, with a degradation range of 4.9%-19.0%. The corrosion degradation of the shear bearing capacity of the connection can be delayed after the friction surface is treated with an anti-corrosion coating. The anti-corrosion ability of the external anti-corrosion coating of the steel structure will gradually decrease after maintenance. Through the anti-slip tests of friction-type connections with high-strength bolts, the effect of corrosion on the shear performance of friction-type connections with high-strength bolts under different preset conditions (internal and external anti-corrosion coating, external anti-corrosion coating maintenance) in a simulated C4 atmospheric corrosion environment was investigated. It is concluded that the degree of degradation of the shear bearing capacity of friction-type connections with high-strength bolts without external anti-corrosion coating is about 1.5-1.8 times that of the specimens with external anti-corrosion coating. In the C4 atmospheric corrosion environment, the reduction of the anti-slip coefficient is the main factor affecting the degradation of the shear bearing capacity of friction-type connections with high-strength bolts with external anti-corrosion coating. The loss of the pre-tightening force of high-strength bolts is the main reason for friction-type connections with high-strength bolts without external anti-corrosion coating.

     

  • loading
  • [1]
    ZHANG Gang, ZHAO Xiao-cui, LU Ze-lei, et al. Review and discussion on fire behavior of bridge girders[J]. Journal of Traffic and Transportation Engineering (English Edition), 2022, 9(3): 422-446. doi: 10.1016/j.jtte.2022.05.002
    [2]
    ZHANG Gang, HE Shuan-hai, SONG Chao-jie, et al. Review on fire resistance of steel structural bridge girders[J]. China Journal of Highway and Transport, 2021, 34(1): 1-10. doi: 10.3969/j.issn.1001-7372.2021.01.001
    [3]
    HE Xiao-yu, XIA Hong-jie, XU Xiao-mei, et al. Study on anticorrosive technology of connecting bolts of bridge steel members in marine atmospheric environment[J]. Equipment Environmental Engineering, 2023, 20(1): 76-82.
    [4]
    TAO Xiao-yan, SHEN Jia-hua, SHI Zhi-qiang. Development history and prospect of high strength bolt connection of steel bridge in China[J]. Railway Engineering, 2017, 59(9): 1-4. doi: 10.3969/j.issn.1003-1995.2017.09.01
    [5]
    CHEN Kai-li, YE Qing-zao. Remedial measures for high-strength bolts deterioration and research on novel-type bolts for steel bridges in Japan[J]. World Bridge, 2021, 49(4): 98-105. doi: 10.3969/j.issn.1671-7767.2021.04.015
    [6]
    ZHANG Meng. Corrosion of high strength steel bolt friction type connection test of performance degradation[D]. Xi'an: Xian University of Architecture and Technology, 2011.
    [7]
    YU Dong. Study on corrosion and its influence on mechanical properties of steel bridge structure[D]. Nanchang: East China Jiaotong University, 2016.
    [8]
    GUO Jia-qi. Analysis and experimental study on mechanical properties degradation of corroded high strength bolt joints[D]. Dalian: Dalian University of Technology, 2020.
    [9]
    WANG Hui-li, TANG Fu-jian, QIN Si-feng, et al. Corrosion -induced mechanical degradation of high-strength bolted steel connection[J]. Journal of Materials in Civil Engineering, 2020, 32(8): 04020203. doi: 10.1061/(ASCE)MT.1943-5533.0003275
    [10]
    HONG Shao-zheng. Research on carrying capacity of corroded high-strength bolt shear connections[D]. Ma'anshan: Anhui University of Technology, 2021.
    [11]
    KONG Zheng-yi, YANG Fan, JIN Ya, et al. Experimental study on bearing capacity of corroded high-strength bolt connections under shear force[J]. Construction and Building Materials, 2021, 309: 125117. doi: 10.1016/j.conbuildmat.2021.125117
    [12]
    JIANG C, XIONG W, CAI C S, et al. Experimental study on the shear behavior of friction connections with corrosion damage[J]. Journal of Constructional Steel Research, 2021, 197: 107449.
    [13]
    AHNJ H, LEE J M, CHEUNG J H, et al. Clamping force loss of high-strength bolts as a result of bolt head corrosion damage: experimental research A[J]. Engineering Failure Analysis, 2016, 59: 509-525. doi: 10.1016/j.engfailanal.2015.08.037
    [14]
    KIMI T, LEE J M, HUH J, et al. Tensile behaviors of friction bolt connection with bolt head corrosion damage: Experimental research B[J]. Engineering Failure Analysis, 2016, 59: 526-543. doi: 10.1016/j.engfailanal.2015.08.038
    [15]
    LI Ming, YAO Ling-bo, ZHANG Shuo-shuo, et al. Study on bolt head corrosion influence on the clamping force loss of high strength bolt[J]. Engineering Failure Analysis, 2021, 129: 105660. doi: 10.1016/j.engfailanal.2021.105660
    [16]
    ISO 12944-2: 2017, Paints and varnishes-corrosion protection of steel structures by protective paint system-Part 2: classification of environments[S].
    [17]
    JIN Wei-feng. Corrosion analysis of existing large span steel structure space pipe truss[J]. Building Construction, 2022, 44(6): 1410-1412, 1421.
    [18]
    YOU Zhi-yue, LIANG Hui-min, ZHU Rong-qiang, et al. Analysis on the corrosion status of building steel structure in Hainan under tropical marine environment[J]. Engineering and Technology Research, 2022, 7(10): 7-9.
    [19]
    JGJ 82-2011, Technical specification for high strength bolt connections of steel structures[S].
    [20]
    JTG D64-2015, Specifications for design of highway steel bridge[S].
    [21]
    GB/T 19292.1-2018, Corrosion of metals and alloys- Corrosivity of atmospheres-Parts 1: classification, determination and estimation[S].
    [22]
    JGJ/T251-2011, Technical specification for anti-corrosion of building steel structure[S].
    [23]
    CHEN Yao. Research on the degradation of steel structures for the needs of structural life-cycle design and time-dependent reliability in corrosive environment[D]. Nanjing: Southeast University, 2021.
    [24]
    CECS 343: 2013, Technical specification for painting and anticorrosion of steel structures[S].
    [25]
    CHEN Xin-hua. Anti-slip coefficient test of friction surface of high strength bolted connection[J]. Building Structure, 2010, 40(S1): 209-212.
    [26]
    GB50017-2017, Standard for design of steel structures[S].
    [27]
    GB/T 10125-2021, Corrosion tests in artificial atmospheres-salt spray tests[S].
    [28]
    LIANG Cai-feng, HOU Wen-tai. Atmospheric corrosion of carbon steels and low alloy steels[J]. Corrosion Science and Protection Technology, 1995, 7(3): 183-186.
    [29]
    LIANG Caif-eng, HOU Wen-tai. Sixteen-year atmospheric corrosion exposure study of steels[J]. Journal of Chinese Society for Corrosion and Protection, 2005, 25(1): 1-6. doi: 10.3969/j.issn.1005-4537.2005.01.001
    [30]
    Specification for structural joints using ASTM A325 or A490 bolts[S].
    [31]
    SHI Yong-jiu, SHI Gang, WANG Yuan-qing, et al. Long-time monitoring on strain relaxation of high strength bolts in end-plate connections[J]. Construction Technology, 2004, 33(11): 11-13. doi: 10.3969/j.issn.1002-8498.2004.11.005
    [32]
    YU Lei, WU Dian-han, WANG Hui, et al. Test on the preload loss of stainless steel high-strength bolt connection[J/OL]. Industrial Construction, 2023, http://kns.cnki.net/kcms/detail/11.2068.TU.20230413.1510.002.html.
    [33]
    CHAO J, WEN X, CAI C S, et al. Preload loss of high- strength bolts in friction connections considering corrosion damage and fatigue loading[J]. Engineering Failure Analysis, 2022, 137: 106416. doi: 10.1016/j.engfailanal.2022.106416
    [34]
    GB/T 228.1-2021, Metallic materials-tensile testing-Part 1: method of test at room temperature[S].

Catalog

    Article Metrics

    Article views (1231) PDF downloads(113) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return